| Article |
Name |
 |
 |
 |
| 2.852.0160 |
852 Titrando with diaphragm-less generator cell and Touch Control operating unit |
|
|
 |
|
 |
Coulometer including generator electrode without diaphragm, complete volumetric titration cell and Touch Control.
The coulometric Karl Fischer Titration is the method of choice for low level water determinations (10 μg … 10 mg absolute water content) in liquid, solid and gaseous samples. As it is an absolute method a titer determination is not necessary.
Recommended measuring range coulometry: 10 µg...200 mg absolute water
With the 852 Titrando coulometric as well as volumetric Karl Fischer titrations are carried out straightforwardly and quickly. |
 |
 |
 |
 |
| 2.852.0150 |
852 Titrando with generator electrode without diaphragm |
|
|
 |
|
 |
Coulometer including generator electrode without diaphragm and complete volumetric titration cell.
The coulometric Karl Fischer Titration is the method of choice for low level water determinations (10 μg … 10 mg absolute water content) in liquid, solid and gaseous samples. As it is an absolute method a titer determination is not necessary.
Recommended measuring range coulometry: 10 µg...200 mg absolute water
With the 852 Titrando coulometric as well as volumetric Karl Fischer titrations are carried out straightforwardly and quickly. |
 |
 |
 |
 |
| 2.852.0060 |
852 Titrando with generator electrode with diaphragm and Touch Control |
|
|
 |
|
 |
Coulometer including generator electrode with diaphragm, Touch Control, 801 Stirrer and complete volumetric titration cell.
The coulometric Karl Fischer Titration is the method of choice for low level water determinations (10 μg … 10 mg absolute water content) in liquid, solid and gaseous samples. As it is an absolute method a titer determination is not necessary.
Recommended measuring range coulometry: 10 µg...200 mg absolute water
With the 852 Titrando coulometric as well as volumetric Karl Fischer titrations are carried out straightforwardly and quickly. |
 |
 |
 |
 |
| 2.852.0050 |
852 Titrando with generator electrode with diaphragm |
|
|
 |
|
 |
Coulometer including generator electrode with diaphragm, 801 Stirrer and complete volumetric titration cell.
The coulometric Karl Fischer Titration is the method of choice for low level water determinations (10 μg … 10 mg absolute water content) in liquid, solid and gaseous samples. As it is an absolute method a titer determination is not necessary.
Recommended measuring range coulometry: 10 µg...200 mg absolute water
With the 852 Titrando coulometric as well as volumetric Karl Fischer titrations are carried out straightforwardly and quickly. |
 |
 |
 |
 |
| 2.851.0120 |
851 Titrando with diaphragmless generator electrode and Touch Control operating unit |
|
|
 |
|
 |
Coulometer including generator electrode without diaphragm and Touch Control.
The coulometric Karl Fischer Titration is the method of choice for low level water determinations (10 μg … 10 mg absolute water content) in liquid, solid and gaseous samples. As it is an absolute method a titer determination is not necessary.
With the 851 Titrando coulometric titrations are carried out straightforwardly and quickly.
Recommended measuring range: 10 µg...200 mg absolute water |
 |
 |
 |
 |
| 2.851.0110 |
851 Titrando with diaphragmless generator electrode |
|
|
 |
|
 |
Coulometer including generator electrode without diaphragm.
The coulometric Karl Fischer Titration is the method of choice for low level water determinations (10 μg … 10 mg absolute water content) in liquid, solid and gaseous samples. As it is an absolute method a titer determination is not necessary.
With the 851 Titrando coulometric titrations are carried out straightforwardly and quickly.
Recommended measuring range: 10 µg...200 mg absolute water |
 |
 |
 |
 |
| 2.851.0020 |
851 Titrando with diaphragm-generator electrode and Touch Control operating unit |
|
|
 |
|
 |
Coulometer including generator electrode with diaphragm, Touch Control and 801 Stirrer.
The coulometric Karl Fischer Titration is the method of choice for low level water determinations (10 μg … 10 mg absolute water content) in liquid, solid and gaseous samples. As it is an absolute method a titer determination is not necessary.
With the 851 Titrando coulometric titrations are carried out straightforwardly and quickly.
Recommended measuring range: 10 µg...200 mg absolute water |
 |
 |
 |
 |
| 2.851.0010 |
851 Titrando with generator electrode with diaphragm |
|
|
 |
|
 |
Coulometer including generator electrode with diaphragm and 801 Stirrer.
The coulometric Karl Fischer Titration is the method of choice for low level water determinations (10 μg … 10 mg absolute water content) in liquid, solid and gaseous samples. As it is an absolute method a titer determination is not necessary.
With the 851 Titrando coulometric titrations are carried out straightforwardly and quickly.
Recommended measuring range: 10 µg...200 mg absolute water |
 |
 |
 |
 |
| 2.831.0110 |
831 KF Coulometer with diaphragmless generator electrode |
|
|
 |
|
 |
Economical KF Coulometer with diaphragmless titration cell for water determination right down to trace levels.
The KF Coulometer has established itself for the determination of very small amounts of water. Thanks to its reliability, backlit graphical display, multilingual dialog and easy operation, the 831 KF Coulometer has become standard equipment in many laboratories. The clear display provides information about the relevant titration parameters and gives an unmistakable presentation of the course of titration in the form of a curve showing µg water against time.
Recommended measuring range: 10 µg...200 mg absolute water |
 |
 |
 |
 |
| 2.831.0010 |
831 KF Coulometer including generator electrode with diaphragm |
|
|
 |
|
 |
Affordable KF Coulometer including titration cell with diaphragm for water determination right down to trace levels.
The KF Coulometer has established itself for the determination of very small amounts of water. Thanks to its reliability, backlit graphical display, multilingual dialog and easy operation, the 831 KF Coulometer has become standard equipment in many laboratories. The clear display provides information about the relevant titration parameters and gives an unmistakable presentation of the course of titration in the form of a curve showing µg water against time.
Recommended measuring range: 10 µg...200 mg absolute water |
 |
 |
 |
 |
| 2.756.0110 |
756 KF Coulometer including diaphragmless generator electrode |
|
|
 |
|
 |
KF Coulometer with titration cell without diaphragm and integrated printer for water determination right down to trace levels. The 756 KF Coulometer has established itself for the determination of very small amounts of water. Thanks to its reliability, backlit graphical display, multilingual dialog and easy operation, the 756 KF Coulometer has become standard equipment in many laboratories. The clear display provides information about the relevant titration parameters and gives an unmistakable presentation of the course of titration in the form of a curve showing µg water against time. Recommended measuring range: 10 µg...200 mg absolute water |
 |
 |
 |
 |
| 2.756.0010 |
756 KF Coulometer including generator electrode with diaphragm |
|
|
 |
|
 |
KF Coulometer with integrated printer and titration cell with diaphragm for water determination right down to trace levels. The 756 KF Coulometer has established itself for the determination of very small amounts of water. Thanks to its reliability, backlit graphical display, multilingual dialog and easy operation, the 756 KF Coulometer has become standard equipment in many laboratories. The clear display provides information about the relevant titration parameters and gives an unmistakable presentation of the course of titration in the form of a curve showing µg water against time. Recommended measuring range: 10 µg...200 mg absolute water |
 |
 |
 |