| Article |
Name |
 |
 |
 |
| 2.901.0010 |
901 Titrando |
|
|
 |
|
 |
The Karl Fischer Titrando for the modern titration laboratory In addition to the Karl Fischer mode (KFT), this high-end titrator also includes the SET mode, which means that titrations can be carried out to a predefined endpoint. "ITrode ready": The high-resolution, galvanically separated measuring interface - now also with additional digital measuring input for intelligent electrodes «iTrodes» - means that it is also possible to make high-precision pH measurements. Thanks to its four MSB connections up to four 800 Dosino dosing systems can be connected to the 901 Titrando. These can be used for titration as well as for the automated addition of sample, standard and auxiliary solutions such as solubility promoters. All liquid handling commands are also available, which means that the aspiration of used reagent and the addition of fresh solvent can be automated. |
 |
 |
 |
 |
| 2.890.0210 |
890 Titrando with tiamoTM light |
|
|
 |
|
 |
| High-end titrator with built-in buret drive for volumetric Karl Fischer titrations. With four MSB connections, one measuring interface and USB connection. Including tiamoTM light, 803 Titration Stand and exchange unit 10 mL. |
 |
 |
 |
 |
| 2.890.0110 |
890 Titrando with Touch Control |
|
|
 |
|
 |
| High-end titrator with built-in buret drive for volumetric Karl Fischer titrations. With four MSB connections, one measuring interface and USB connection. Including Touch Control, 803 Titration Stand and exchange unit 10 mL. |
 |
 |
 |
 |
| 2.852.0160 |
852 Titrando with diaphragm-less generator cell and Touch Control operating unit |
|
|
 |
|
 |
Coulometer including generator electrode without diaphragm, complete volumetric titration cell and Touch Control.
The coulometric Karl Fischer Titration is the method of choice for low level water determinations (10 μg … 10 mg absolute water content) in liquid, solid and gaseous samples. As it is an absolute method a titer determination is not necessary.
Recommended measuring range coulometry: 10 µg...200 mg absolute water
With the 852 Titrando coulometric as well as volumetric Karl Fischer titrations are carried out straightforwardly and quickly. |
 |
 |
 |
 |
| 2.852.0150 |
852 Titrando with generator electrode without diaphragm |
|
|
 |
|
 |
Coulometer including generator electrode without diaphragm and complete volumetric titration cell.
The coulometric Karl Fischer Titration is the method of choice for low level water determinations (10 μg … 10 mg absolute water content) in liquid, solid and gaseous samples. As it is an absolute method a titer determination is not necessary.
Recommended measuring range coulometry: 10 µg...200 mg absolute water
With the 852 Titrando coulometric as well as volumetric Karl Fischer titrations are carried out straightforwardly and quickly. |
 |
 |
 |
 |
| 2.852.0060 |
852 Titrando with generator electrode with diaphragm and Touch Control |
|
|
 |
|
 |
Coulometer including generator electrode with diaphragm, Touch Control, 801 Stirrer and complete volumetric titration cell.
The coulometric Karl Fischer Titration is the method of choice for low level water determinations (10 μg … 10 mg absolute water content) in liquid, solid and gaseous samples. As it is an absolute method a titer determination is not necessary.
Recommended measuring range coulometry: 10 µg...200 mg absolute water
With the 852 Titrando coulometric as well as volumetric Karl Fischer titrations are carried out straightforwardly and quickly. |
 |
 |
 |
 |
| 2.852.0050 |
852 Titrando with generator electrode with diaphragm |
|
|
 |
|
 |
Coulometer including generator electrode with diaphragm, 801 Stirrer and complete volumetric titration cell.
The coulometric Karl Fischer Titration is the method of choice for low level water determinations (10 μg … 10 mg absolute water content) in liquid, solid and gaseous samples. As it is an absolute method a titer determination is not necessary.
Recommended measuring range coulometry: 10 µg...200 mg absolute water
With the 852 Titrando coulometric as well as volumetric Karl Fischer titrations are carried out straightforwardly and quickly. |
 |
 |
 |
 |
| 2.851.0120 |
851 Titrando with diaphragmless generator electrode and Touch Control operating unit |
|
|
 |
|
 |
Coulometer including generator electrode without diaphragm and Touch Control.
The coulometric Karl Fischer Titration is the method of choice for low level water determinations (10 μg … 10 mg absolute water content) in liquid, solid and gaseous samples. As it is an absolute method a titer determination is not necessary.
With the 851 Titrando coulometric titrations are carried out straightforwardly and quickly.
Recommended measuring range: 10 µg...200 mg absolute water |
 |
 |
 |
 |
| 2.851.0110 |
851 Titrando with diaphragmless generator electrode |
|
|
 |
|
 |
Coulometer including generator electrode without diaphragm.
The coulometric Karl Fischer Titration is the method of choice for low level water determinations (10 μg … 10 mg absolute water content) in liquid, solid and gaseous samples. As it is an absolute method a titer determination is not necessary.
With the 851 Titrando coulometric titrations are carried out straightforwardly and quickly.
Recommended measuring range: 10 µg...200 mg absolute water |
 |
 |
 |
 |
| 2.851.0020 |
851 Titrando with diaphragm-generator electrode and Touch Control operating unit |
|
|
 |
|
 |
Coulometer including generator electrode with diaphragm, Touch Control and 801 Stirrer.
The coulometric Karl Fischer Titration is the method of choice for low level water determinations (10 μg … 10 mg absolute water content) in liquid, solid and gaseous samples. As it is an absolute method a titer determination is not necessary.
With the 851 Titrando coulometric titrations are carried out straightforwardly and quickly.
Recommended measuring range: 10 µg...200 mg absolute water |
 |
 |
 |
 |
| 2.851.0010 |
851 Titrando with generator electrode with diaphragm |
|
|
 |
|
 |
Coulometer including generator electrode with diaphragm and 801 Stirrer.
The coulometric Karl Fischer Titration is the method of choice for low level water determinations (10 μg … 10 mg absolute water content) in liquid, solid and gaseous samples. As it is an absolute method a titer determination is not necessary.
With the 851 Titrando coulometric titrations are carried out straightforwardly and quickly.
Recommended measuring range: 10 µg...200 mg absolute water |
 |
 |
 |